Grade – BI 12/1,3

TECHNICAL DATA SHEET
Name of the product: insulating concrete
Classification: BI 12/1,3
Properties Unit BI 12/1,3 BI 12/1,3
Method of application cast gun
Temperature limit of application, max oC 1200 1200
Cold crushing strength, min

  • After drying at 105 oC, min
  • After firing at the temperature of application after 2 h, min
MPa 12,0
7,5
14,0
8,0
Bulk density after firing at temperature limit of application, min g/cm3 1,3 1,35
Thermal conductivity:

  • 400 ºC
  • 600 ºC
  • 800 ºC
  • 1000 ºC
W/mK

 

0,32
0,35
0,40
0,52

 

0,33
0,36
0,42
0,54

The indicated technical data are for information only and are not to be viewed as guaranteed values.